info@biomedres.us   +1 (720) 414-3554
  One Westbrook Corporate Center, Suite 300, Westchester, IL 60154, USA

Biomedical Journal of Scientific & Technical Research

January, 2020, Volume 24, 5, pp 18641-18644

Research Article

Research Article

The Accuracy of Ultrasonography in the Diagnosis of Fetal Head Engagement

Zakia M Ibrahim, Waleed A Sayed Ahmed, Mohamed A Elmorsy, Magda M Albiely and Omima T Taha*

Author Affiliations

Department of Obstetrics and Gynecology, Egypt

Received: January 11, 2020 | Published: January 23, 2020

Corresponding author: Omima T Taha, Department of Obstetrics and Gynecology, Faculty of Medicine, Suez Canal University, Round Road, Ismailia 41111, Egypt

DOI: 10.26717/BJSTR.2020.24.004119

Abstract

A successful vaginal birth is the art of obstetrics. Many concerns exist regarding this event that raises patients’ anxiety. The main concern is the possibility of having a successful vaginal delivery. Many methods are present to detect fetal head engagement, which plays a significant role in the event of vaginal birth. The digital vaginal examination was the first method to diagnose it. However, it has been stated that digital vaginal examination was painful, causing great distress to patients. This study aimed at evaluation of the accuracy of three different modalities in the diagnosis of fetal head engagement using transabdominal ultrasound, transperineal ultrasound, and digital vaginal examination. This was a cross-sectional analytical study carried out in the emergency and delivery ward of the obstetrics and gynecology department of Suez Canal university hospitals from January 2018 to June 2019. We recruited sixty-six nulliparous women and the examination was carried out while in the latent phase of labor. The mean age was 29.2 ± 1.5, and the gestational age had a median of 38 weeks.

The fetal head engagement was diagnosed in 60 (90.0%) of patients using transvaginal digital examination. The fetal head engagement was documented in 55 patients only by transabdominal ultrasound, with a percent agreement of 91.7% and a p-value of 0.0001. Occipitoanterior position was recorded in 59/66 patients (89.4%). The head- perineum distance was reported to be 52.2 mm ± 6.1. The fetal head engagement was reported in 56/66 (84.8 %) patients, with a percent agreement of 93.3 % and a p-value of 0.0001. A head – perineum distance of 60 mm had a sensitivity and specificity of 100% and 91% in the prediction of fetal head engagement, respectively. Transperineal ultrasound was more accurate to detect fetal head engagement. It also had a high sensitivity and specificity when using the head- perineum distance.

Keywords: Abdominal ultrasound; Digital vaginal examination; Fetal head engagement; Perineal ultrasound; Vaginal delivery

Introduction

There are two paramount queries in the philosophy of labor: when and how to deliver. The answer to these questions is extremely hard. Besides, the pregnant woman is very anxious about her chances of having a vaginal delivery or a cesarean birth. We must consider other risk factors that may import a sudden modification in the course of labor with our aim to maintain maternal and fetal safety [1]. Previous researches showed that digital vaginal examination (DVE) might fail to identify fetal head position accurately. In these situations, ultrasound proved to be more effective [2], with a reduced error in the diagnosis of fetal head position and progression especially during labor [3]. Fetal head engagement is defined as the passage of the biparietal diameter from the pelvic inlet [4]. This commonly occurs in nulliparous women from gestational age 36 weeks, while most of them will present in labor with the head not engaged [5]. The role of intrapartum ultrasound was previously reported to be useful in certain circumstances such as before the use of instrumental delivery [6]. Intrapartum ultrasound was found to be more accurate with less discomfort than digital vaginal examination [2]. The current study aimed at comparing the accuracy of three methods of diagnosing fetal head engagement (digital vaginal examination, transabdominal ultrasound, and transvaginal ultrasound).

Patients and Methods

This was a cross-sectional analytical study. It was conducted in the labor and delivery ward of the obstetrics and gynecology department, Suez Canal university hospitals from January 2018 to June 2019. Patients were recruited according to the following inclusion criteria: a) Age 18-35years old, b) Primigravida, c) Singleton fetus, d) Cephalic presentation, e) gestational age ≥ 37 weeks, and f) in the latent phase of labor. Patients who refused to participate in the study or to continue with the study protocol were excluded. Eligible patients were subjected to the following: a) History taking, including personal data, menstrual history to confirm the gestational age, and symptoms of fetal head engagement (frequency of micturition, difficulty in walking, rectal tenesmus, lightening), b) Clinical examination included a general examination and abdominal examination. On abdominal examination, fetal head engagement was documented when only two-fifths of the fetal head was palpable [7]. Alternatively, when the BPD of the fetus has descended through the pelvic inlet, the examining fingers cannot reach the lowermost part of the fetal head; as a result when pushed down over the abdomen the examining fingers slide over that portion of the fetal head proximal to the BPD and diverge. Conversely, if the fetal head is not engaged, the examining fingers can easily palpate the lower part of the fetal head and will converge (the fourth Leopold maneuver) [8] (Tables 2 & 3).

Finally, a local examination was done with digital pelvic examination (assessment of pelvic capacity, confirm presentation, confirm position, detect engagement and station, detect degree of deflection). On transvaginal assessment, engagement of the fetal head was considered to have usually (but not always) occurred when the presenting part (typically the parietal bone) was positioned at maternal ischial spine station [9] (Table 4).

Ultrasound Examination was Performed

Transabdominal Ultrasonography (TAS): Initially, the patient was placed in a sitting position and the level of the lumbar vertebrae L5 and S1 (sacral promontory) was demarcated (utilizing the posterior superior iliac spines and superior aspect of the median sacral crest) [10]. The woman was later placed in a supine position, to demarcate the pelvic inlet, and the transabdominal transducer was placed transversely above the symphysis pubis and directed cephalad towards the maternal sacral promontory. The sacral promontory, although not visible sonographically due to the presence of the fetal skull, is considered to be positioned between L5 and S1, i.e. at the level marked previously [11]. Utilizing midline intracranial structures (cavum septum pellucidum, falx cerebri, and thalami), the level of the BPD was ascertained. When the BPD was located below the line extending between the superior aspect of the maternal symphysis pubis and the maternal sacral promontory (demarcating the pelvic inlet), the fetal head was considered to be engaged; conversely it was not engaged when the BPD was depicted at an angle above the pelvic inlet.

Transperineal Ultrasonography (TPS): It was performed with the woman in a supine position and with an empty bladder. The shortest distance from the outer bony limit of the fetal skull to the skin surface of the perineum was measured in a transverse view, with the probe held over the ischial tuberosity with firm pressure, but without creating any discomfort to the woman. This distance was measured in all women. The midpoint of the pelvic canal is at the level of the ischial spine. The distance from the perineum to the ischial spine is 5 cm, according to the World Health Organization (WHO) stages of head descent. The fetal head–perineum distance was measured by transperineal ultrasound imaging as the shortest distance from the outer bony limit of the fetal skull to the skin surface of the perineum [12]. Both ultrasound methods were compared to findings obtained on vaginal palpation of the fetal head. Examiners were blinded to each other’s results.

Results

The mean age was 29.2 ± 1.5, and the gestational age had a median of 38 weeks. The fetal head engagement was diagnosed in 60 (90.0%) of patients using transvaginal digital examination (Table 1). Using trans-abdominal ultrasound, fetal head engagement was documented in 55 patients only, with a percent agreement of 91.7% and a p-value of 0.0001 (Table 2). Occipitoanterior position was recorded in 59/66 patients (89.4%) (Table 3). The perineal head distance was reported to be 52.2 mm ± 6.1 (Table 4). The fetal head engagement was reported in 56/66 (84.8 %) patients, with a percent agreement of 93.3 % and a p-value of 0.0001. A head – perineum distance of 60 mm had a sensitivity and specificity of 100% and 91% in the prediction of fetal head engagement, respectively (Tables 5 and 6).

Table 1: Relation of engagement as detected by DVE to fetal head position and mode of delivery.

Table 2: Agreement between fetal head engagement as detected by DVE and TAS.

Table 3: Relation of engagement as detected by TAS and head position and mode of delivery.

Table 4: Perineum-fetal head distance as detected by transperineal ultrasound (TPS).

Table 5: Cut-off, sensitivity, specificity, positive predictive value, negative predictive value and accuracy of perineum-fetal head distance for the prediction of fetal head engagement.

Table 6: Agreement between fetal head engagement as detected by DVE and TPS.

Discussion

We recruited nulliparous patients with a mean age of 29.2 ± 1.5 and a median gestational age of 38 weeks. The fetal head engagement was diagnosed in 60 (90.0%) of patients using transvaginal digital examination. Using trans-abdominal ultrasound, fetal head engagement was documented in 55 patients only, with a percent agreement of 91.7% and a p-value of 0.0001. A slightly higher percentage was reported using transperineal ultrasound (56 patients, with a percent agreement of 93.3% and a p-value of 0.0001). This was higher than what was published in a previous study [2]. This could be attributed to the difference in the studied population as the study above recruited nulliparous women as well as multiparous ones while the current study recruited nulliparous women only. Occipitoanterior position was the predominant fetal head position occurring in 59/66 patients (89.4%). This was higher than what was reported by Akmal et al. (65.6%). This would be explained by performing digital vaginal examination by consultant level specialists in 17% of cases (n = 11) or by trainees with different years of experience in obstetrics and gynecology, with a resultant failure to identify fetal head position in 26.6% of cases [6]. “However; digital vaginal examination was performed by senior specialists only in this study.

The fetal head engagement was ascertained in 57/60 (95%), 53/55 (96.4%) patients with an occiput anterior position using digital vaginal examination and trans-abdominal ultrasound, respectively. This was higher than previous study in which accurate determination of fetal head station was documented in 75% of patients. The accuracy increases in cases with occiput anterior position and when the head is below the level of the ischial spines [6]. The fetal head engagement was documented in 52/60 (86.7%), 47/ 55 (85.5%) patients who delivered vaginally, using digital vaginal examination and trans-abdominal ultrasound respectively. Transperineal ultrasound was comfortable to perform and tolerable for the patients as reported previously [13]. The head- perineum distance was said to be 52.2 mm ± 6.1. The fetal head engagement was reported in 56/66 (84.8 %) patients, with a percent agreement of 93.3% and a p-value of 0.0001. A head – perineum distance of 60 mm had a sensitivity and specificity of 100% and 91% in the prediction of fetal head engagement, respectively. This study compared the above mentioned three methods for fetal head engagement with the transperineal ultrasound reported to be more accurate. A more extensive meta-analysis needs to be conducted to draw reliable recommendations from the previous studies. Obstetricians should be trained on performing transperineal ultrasound to determine fetal head position and engagement especially when the bony landmarks are obscured. The recruitment of multiparous women should be recommended with further subanalysis of the accuracy of these modalities with different parities.

Conflicts of Interest

None.

Ethical Approval

All procedures performed in in the study were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This article did not contain any studies with animals performed by any of the authors.

Informed Consent

was obtained from all participants before enrollment in the study.

Funding

This was self-funded research

References

Research Article

The Accuracy of Ultrasonography in the Diagnosis of Fetal Head Engagement

Zakia M Ibrahim, Waleed A Sayed Ahmed, Mohamed A Elmorsy, Magda M Albiely and Omima T Taha*

Author Affiliations

Department of Obstetrics and Gynecology, Egypt

Received: January 11, 2020 | Published: January 23, 2020

Corresponding author: Omima T Taha, Department of Obstetrics and Gynecology, Faculty of Medicine, Suez Canal University, Round Road, Ismailia 41111, Egypt

DOI: 10.26717/BJSTR.2020.24.004119

Abstract

A successful vaginal birth is the art of obstetrics. Many concerns exist regarding this event that raises patients’ anxiety. The main concern is the possibility of having a successful vaginal delivery. Many methods are present to detect fetal head engagement, which plays a significant role in the event of vaginal birth. The digital vaginal examination was the first method to diagnose it. However, it has been stated that digital vaginal examination was painful, causing great distress to patients. This study aimed at evaluation of the accuracy of three different modalities in the diagnosis of fetal head engagement using transabdominal ultrasound, transperineal ultrasound, and digital vaginal examination. This was a cross-sectional analytical study carried out in the emergency and delivery ward of the obstetrics and gynecology department of Suez Canal university hospitals from January 2018 to June 2019. We recruited sixty-six nulliparous women and the examination was carried out while in the latent phase of labor. The mean age was 29.2 ± 1.5, and the gestational age had a median of 38 weeks.

The fetal head engagement was diagnosed in 60 (90.0%) of patients using transvaginal digital examination. The fetal head engagement was documented in 55 patients only by transabdominal ultrasound, with a percent agreement of 91.7% and a p-value of 0.0001. Occipitoanterior position was recorded in 59/66 patients (89.4%). The head- perineum distance was reported to be 52.2 mm ± 6.1. The fetal head engagement was reported in 56/66 (84.8 %) patients, with a percent agreement of 93.3 % and a p-value of 0.0001. A head – perineum distance of 60 mm had a sensitivity and specificity of 100% and 91% in the prediction of fetal head engagement, respectively. Transperineal ultrasound was more accurate to detect fetal head engagement. It also had a high sensitivity and specificity when using the head- perineum distance.

Keywords: Abdominal ultrasound; Digital vaginal examination; Fetal head engagement; Perineal ultrasound; Vaginal delivery